Call us: +44 870 8 200 310
Or write: experts@regartis.com
Monitor substances in REACH with EcoMole Watchdog.
COLUMN 1 STANDARD INFORMATION REQUIRED |
COLUMN 2 SPECIFIC RULES FOR ADAPTATION FROM COLUMN 1 |
7.1. State of the substance at 20 °C and 101,3 kPa |
|
7.2. Melting/freezing point |
7.2. The study does not need to be conducted below a lower limit of - 20 °C. |
7.3. Boiling point |
7.3. The study does not need to be conducted: — for gases, or — for solids which either melt above 300 °C or decompose before boiling. In such cases the boiling point under reduced pressure may be estimated or measured, or — for substances which decompose before boiling (e.g. auto-oxidation, rearrangement, degradation, decomposition, etc.). |
7.4. Relative density |
7.4. The study does not need to be conducted if: — the substance is only stable in solution in a particular solvent and the solution density is similar to that of the solvent. In such cases, an indication of whether the solution density is higher or lower than the solvent density is sufficient, or — the substance is a gas. In this case, an estimation based on calculation shall be made from its molecular weight and the Ideal Gas Laws. |
7.5. Vapour pressure |
7.5. The study does not need to be conducted if the melting point is above 300 °C. If the melting point is between 200 °C and 300 °C, a limit value based on measurement or a recognised calculation method is sufficient. |
7.6. Surface tension |
7.6. The study need only be conducted if: — based on structure, surface activity is expected or can be predicted, or — surface activity is a desired property of the material. If the water solubility is below 1 mg/l at 20 °C the test does not need to be conducted. |
7.7. Water solubility |
7.7. The study does not need to be conducted if: — the substance is readily oxidisable in water. If the substance appears ‘insoluble’ in water, a limit test up to the detection limit of the analytical method shall be performed. |
7.8. Partition coefficient n-octanol/water |
7.8. The study does not need to be conducted if the substance is inorganic. If the test cannot be performed (e.g. the substance decomposes, has a high surface activity, reacts violently during the performance of the test or does not dissolve in water or in octanol, or it is not possible to obtain a sufficiently pure substance), a calculated value for log P as well as details of the calculation method shall be provided. |
7.9. Flash-point |
7.9. The study does not need to be conducted if: — the substance is inorganic, or — the substance only contains volatile organic components with flash-points above 100 °C for aqueous solutions, or — the estimated flash-point is above 200 °C, or — the flash-point can be accurately predicted by interpolation from existing characterised materials. |
7.10. Flammability |
7.10. The study does not need to be conducted: — if the substance is a solid which possesses explosive or pyrophoric properties. These properties should always be considered before considering flammability, or — for gases, if the concentration of the flammable gas in a mixture with inert gases is so low that, when mixed with air, the concentration is all time below the lower limit, or — for substances which spontaneously ignite when in contact with air. |
7.11. Explosive properties |
7.11. The study does not need to be conducted if: — there are no chemical groups associated with explosive properties present in the molecule, or — the substance contains chemical groups associated with explosive properties which include oxygen and the calculated oxygen balance is less than -200, or — the organic substance or a homogenous mixture of organic substances contains chemical groups associated with explosive properties, but the exothermic decomposition energy is less than 500 J/g and the onset of exothermic decomposition is below 500 °C, or — for mixtures of inorganic oxidising substances (UN Division 5.1) with organic materials, the concentration of the inorganic oxidising substance is: — — less than 30 %, by mass, if assigned to UN Packaging Group III (low hazard). Note: Neither a test for propagation of detonation nor a test for sensitivity to detonative shock is required if the exothermic decomposition energy of organic materials is less than 800 J/g. |
7.12. Self-ignition temperature |
7.12. The study does not need to be conducted: — if the substance is explosive or ignites spontaneously with air at room temperature, or — for liquids non flammable in air, e.g. no flash point up to 200 °C, or — for gases having no flammable range, or |
7.13. Oxidising properties |
7.13. The study does not need to be conducted if: — the substance is explosive, or — the substance is highly flammable, or — the substance is an organic peroxide, or — the substance is incapable of reacting exothermically with combustible materials, for example on the basis of the chemical structure (e.g. organic substances not containing oxygen or halogen atoms and these elements are not chemically bonded to nitrogen or oxygen, or inorganic substances not containing oxygen or halogen atoms). The full test does not need to be conducted for solids if the preliminary test clearly indicates that the test substance has oxidising properties. Note that as there is no test method to determine the oxidising properties of gaseous mixtures, the evaluation of these properties must be realised by an estimation method based on the comparison of the oxidising potential of gases in a mixture with that of the oxidising potential of oxygen in air. |
7.14. Granulometry |
7.14. The study does not need to be conducted if the substance is marketed or used in a non solid or granular form. |